NIF 55 PART A
PRODUCT NAME: NIF 55 PART A
HMIS CODES: H F R F
PRODUCT CODE: 145 A 2* 3 0 G
SECTION I -- MANUFACTURER IDENTIFICATION
MANUFACTURER'S NAME: NORTHERN INDUSTRIAL FLOORING, INC.
ADDRESS: 8140 W 350 N ANGOLA, IN 46703
EMERGENCY PHONE: BETCO 419-241-2156 INFORMATION PHONE: 800-424-8914
DATE REVISED: 03-28-96 NAME OF PREPARER: HARRY JACKSON
SECTION II -- HAZARDOUS INGREDIENTS/SARA III INFORMATION
OCCUPATIONAL EXPOSURE LIMITS VAPOR PRESSURE WEIGHT
HAZARDOUS COMPONENTS CAS NUMBER OSHA PEL ACGI TLV OSHA STEL mm HG @ TEMP PERCENT
---------------------------------------------------------------------------------------------
SOLID EPOXY RESIN 25036-25-3 NONE NONE NONE N/A
*METHYL ISOBUTYL KETONE 108-10-1 50PPM 50PPM 75PPM N/A 14
*XYLENE 1330-20-7 100PPM 100PPM 150PPM N/A 23
*Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372.
ACOIH STEL=75 FOR MIBK. ACGIS STEL = 150PPM FOR XYLENE. FOLLOW TSCA 8 (d) 40 CFR 47 FR 387: RCRA 40 CFR 261;
CNA 311 (b)(2)(a) 40 CFR 116, 117 GUIDELINES. KNOWN HAZARDOUS WASTE NUMBERS ARE XYLENE = U239; MIBK = U161.
SECTION III -- PHYSICAL/CHEMICAL CHARACTERISTICS
BOILING POINT: 144 DEG F SPECIFIC GRAVITY (H2O=1): 1.0
VAPOR DENSITY: N/A EVAPORATION RATE: N/A
SOLUBILITY IN WATER: NEGLIGIBLE
APPEARANCE AND ODOR: PALE YELLOW LIQUID WITH SOLVENT ODOR
SECTION IV -- FIRE AND EXPLOSION HAZARD DATA
FLASH POINT: 84 f METHOD USED: SETA FLASH
FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: N/A UPPER: N/A
EXTINGUISHING MEDIA: FOAM, ALCOHOL FOAM, CO2, DRY CHEMICAL
SPECIAL FIREFIGHTING PROCEDURES
DO NOT ENTER CONFINES FIRE AREA WITHOUT FULL BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL ALL FIRE EXPOSED CONTAINERS WITH WATER. PRESENCE OF SOLVENTS IN PRODUCT MAY REQUIRE GROUNDING.
UNUSUAL FIRE AND EXPLOSION HAZARDS
IF FIRE OCCURS, SOLVENTS MAY PRODUCE EXCESSIVE PRESSURE. SEALED DRUMS MAY RUPTURE AND IGNITE. VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG THE GROUND AND IGNITE BY ANY SOURCE OF IGNITION. NEVER USE A CUTTING OR WELDING TORCH NEAR CONTAINERS (EVEN EMPTY). ALL 5 GALLON AND LARGER CONTAINERS SHOULD BE GROUNDED BEFORE TRANSFERRING MATERIAL.